1/5
Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW)图1Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW)图2

Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW)

$57.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Single/Three Phase Industrial Diesel Synchronous Brushless AC Alternator (80-200KW) Model NO.: TBS Brand: Tongbo Certification: ISO9001, CCC Starting Mode: Variable Frequency Starting Number of Poles: 2, 4, 6, 8 Casing Protection: Closed Type Rotor Structure: Squirrel-Cage Species: Tbs Number of Stator: Three-Phase Operating Speed: Constant Speed Application: Industrial Protection Class: IP21 Insulation Class: H Trademark: tongbo Transport Package: Carton/Wooden Case/Wooden Crate Origin: Fujian, China HS Code: 8501520000 Product Description Electric Character:EXCITATION SYSTEM:AVR: SX440, SX460, MX321, MX341The main stator supplies power to the exciter stator via the AVR. The exciter rotor output is provided to the main rotor by a three-phase full wave bridge rectifier. This rectifier is protected by a surge suppressor against surges ecused by short circuit or lost Synchronization. Voltage regulation of SX440 AVR with three phase induction detecting module< ±0.5 %.MX321 and MX341 suitable for the generator with permanent magnetic generator (PMG).Electric FeaturesInsulation And Varnish:The insulation system is class H.All wound components are impregnated with materials and processes designed specifically ensure the generator running in dreadful conditions. The special developed resin materials meet rotating components.Windings and Electrical Performance:All generator stators are wound to 2/3 pitch, This eliminates triple(3rd,9th,15th…)harmonics on the voltage waveform and is an optimum designed for UPS equipment of non linear loads. The 2/3 pitch design avoids excessive neutral currents result from higher winding pitches. A fully consecutive damper winding reduces oscillations during paralleling. The 2/3 pitch windings and carefully pole and tooth ensures very low waveform distortion.Terminals And Terminal Box:Standard generators are 3-phase,and you can reconnect 12 ends of the terminals, which are mounted on a terminal block at the non-drive end of the generator. A sheet steel terminal box within AVR is provided with enough place for the customers'wiring. It has removable panels for easy access.Telephone Influence Factor:THF(BS EN60034-1)<2%THF(NEMA MG1-22)<50 Mechanic Features:SHAFT AND KEYAll generator rotors are dynamically balanced to better than minimum vibration of BS6861: part1 grade 2.5 double bearings generators are banlanced with a half key.ENGINE ADAPTOR AND COUPLINGAll generators are designed two kinds of construction. The adaptor and the drive plate is consonant with SAE standard.LEVELS Of PROTECTIonAll generators are IP2 and IP23 and IP44 can be optional for aircool protected generator. but rated power will decrease 5~10%.The Definition Of The Product Model:Option And AccessoryWindings temp protect thermistor and relayPMGMX321 or MX341Transformer for droop during parallelingTechnical dateModelRated Output(KW)Rated Capacity(KVA)Rated Vottage(V)Rated Current(A)Power Factor(CosфRated Speed(r.p.m)Rated Frequency(Hz)Gro$$ Weight(Kg)TBS164A6.58.140012.30.81500/180050/6095TBS164B8.81140015.80.81500/180050/60102TBS164C10.813.540019.50.81500/180050/60110TBS164012.816400230.81500/180050/60116TBS184E1822.540032.50.81500/180050/60141TBS184F2227.540039.70.81500/180050/60164TBS184G2S31.340045.10.81500/180050/60180TBS184H3037.540054.10.81500/180050/60230TBS184J324040057.70.81500/180050/60240TBS224C3442.540061.40.81500/180050/60225TBS224D405040072.20.81500/180050/60270TBS224E486040086.60.81500/180050/60290TBS224F58725400104.60.81500/180050/60330TBS224G6885400122.70.81500/180050/60370TBS274C80100400144.30.81500/180050/60435TBS274D91114400173.20.81500/180050/60460TB5274E1121404002020.81500/180050/60510TBS274F128160400225.50.81500/180050/60550TBS274G140175400259.80.81500/180050/60550TBS274H160200400288.70.81500/180050/60650TBS314C200250400360.80.81500/180050/60910TBS314D2362954004330.81500/180050/60975TBS314E2603254004690.81500/180050/601055TBS314F304380400548.50.81500/180050/601183TBS354C360450400656.80.81500/180050/601350TBS354D400500400721.70.81500/180050/601450TBS3S4E480600400880.50.81500/180050/601598TBS3S4F536670400967.10.81500/180050/601753REMARKAll the rated are on basis of environment temperature 40#C, altitude not exceeding 1000m.Different temperature offers different standby power, the define of standby power is related to the standard of ISO8528-3.All the rotors are 4 poles, as to other pole generator, please contact the manufacturer.Generators in other voltage range depend on costumers request
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product