1/5
Power Transformer C & Tan Delta / Insulation Power Factor Tester (CDEF)图1Power Transformer C & Tan Delta / Insulation Power Factor Tester (CDEF)图2

Power Transformer C & Tan Delta / Insulation Power Factor Tester (CDEF)

$2.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Power Transformer C & Tan Delta / Insulation Power Factor Tester (CDEF) Model NO.: WGSL-4C Customized: Non-Customized Type: Tan Delta Tester Usage: Electric Component Tester Tan Delta Test Set: Tan Delta Tester 10kv/1A Trademark: GOLDSOL Transport Package: Aluminum Box Inside and Plywood Case Outside Specification: CE Origin: China HS Code: 903033200 Product Description IntroductionInsulating dielectric loss measurementof transformers, transformers, reactors, capacitors, and bushings, surge arresters is a very basic test method can effectively find the overall damp insulation deterioration and local defects of electrical equipment. It is widely used in electrical manufacturing, electrical equipment installation, transfer and preventive tests.WGSL-4C Automatic Frequency Dielectric Loss Tester bridge broke through the traditional measurement, adopting variable frequency power supply technology, SBC and modern electronic technology of automaticly frequency conversion, A / D conversion and data operations; It has the characters of good anti-interference ability, fast test speed, high precision, fully automatic digital and easy to operate; It has a high-power switching power supply to output 45Hz and 55Hz pure sine wave, providing up to 10 kV voltage; It can automatically filter out 50Hz interference suitable for testing at substations and other fields of large electromagnetic interference.Technical parameters1. Input: 180V ~ 270V AC, 1-phase, 50/60Hz ± 1%;2. Test voltage: 0.5 ~ 10 kV, user-selectable (model no.WGSL-5: 0.5-12KV)3. Test current: 200 mA maximum4. Accuracy:Capacitance: +1% of reading + 1pFTan: +1% of reading +. 00040Voltage: +1% of reading.5. Interfernce Supression:Ratio of interference current to specimen current: 2: 1Line frequency modulation technique either by:1) Fixed Frequency measurement:45, 50, 55, 60, 65Hz; User-selectable or2) Dual frequency measurement with automaticAveraging: 45/55Hz, 55/65Hz, 47.5/52.5Hz; User- selectableMeasurement modesUST (Ungrounded specimen test)This test is made when the specimen can be insulated from ground.The test is often used to reduce the effect of stray capacitance Losses to ground and to reduce the effect of interference pickup from nearby Energized apparatus.Typical test specimen include the primary to secondary winding insulation in high Voltage transformers and measurements on HV bushings with a capacitance tap.GST (Grounded specimen test)This is the most frequent used test connection and involves all insulation between The high voltage conductor and ground. Typical test specimens include transformer Windings to tank and core, circuit breaker assemblies, coils of rotating machines, etc.GST-g (Grounded specimen test with guard )This test is used to separate the total values of the GST into separateParts for better analysis. Often this test is used with the GST to confirm the testReadings made using the UST7. Test DurationTypically 40 Seconds, fully automatic testing.The unit automatically ramps up to set test voltage, take measurement, ramps down Voltage to zero and prints out test result.Measurure rangeTest capacitance range @ 50 Hz / 60Hz.1) Internal power supply 200 mA max.3pF ~ 60000p F @ 10kV60pF ~ 1µ F @ 0.5kV2) External power supply, 5A max.3pF ~1.5µ F@10kV3) Resolution: 0.001pF, 4 digitsTgδ Range: Unlimited, resolution. 0001% Voltage: 0~10kV, it can automatically identify capacitance/Inductance/Resistance.Current: 10µ A~5A9. Built-in PrinterThermal printer10. Operator Safety And ProtectionThe tester is equipped with self-diagnostic procedures, protection Against short circuits, open and poor ground connection, Input over-voltage and audible sound, flashing light indicators during test.11. Environment1) Operating temperature: -10 to 600C2) Storage temperature: -200C to 600C3) Relative humidity: <90% non-condensing12. Accessories Supplied1) HV cable with hook and clip2) 2 sets of Cx and Cn cables with clips3) Guard cable with clips4) Paper roll, fuses in a cable bag13. Dimension: 460mm L X 350mm W X 340mm HWeight: Unit: 28 kg; Cable: 3.5 kg
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product