1/5
Cotrust Em231 8ai*16bit Analog Voltage Input Module PLC Logic Controller Compatible Siemens图1Cotrust Em231 8ai*16bit Analog Voltage Input Module PLC Logic Controller Compatible Siemens图2

Cotrust Em231 8ai*16bit Analog Voltage Input Module PLC Logic Controller Compatible Siemens

$160.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Cotrust Em231 8ai*16bit Analog Voltage Input Module PLC Logic Controller Compatible Siemens Model NO.: CTS7-231-0HF32 Customized: Customized Condition: New Certification: RoHS, ISO: 9001, CE Function: Automatic Control Signal: Continuous Structure: Combination Task: Program Weight: 0.2kg Trademark: COTRUST Transport Package: CTN Specification: 71.2*80*62mm Origin: China HS Code: 853710119 Product Description Performance ParametersSpecificationEM231, 8 AI×16BITPhysical Features Dimensions(W×H×D)71.2×80×62mm Power Loss(dissipation)1WPower Consumption From +5V(from I/O bus)25 mA From L+30 mA L+ voltage range,class 2orDC sensor supply20.4~28.8V DC LED indicator24 VDC Power Supply Good ON = no fault, OFF = no 24 VDC powerAnalog Input Feature Number of analog input points8 points Isolation(field side to logic circuit)500V AC for 1 minute input typeDifferentialInput Range current ( unipolar )0-20mA ,4-20mA Data Range Bipolar, full-scale range0~32000Input Resolution Current (unipolar)0.000625mA (0~20mA)0.0005mA (4~20mA) Analog to digital conversion timeabout 10ms Analog input step responseabout 80ms Common mode rejection40dB,DC to 60Hz Common mode voltageSignal voltage plus Common mode voltage must be ≤±12V Input Impedance250Ω Input filter attenuation-3db @ 3.1kHz Maximum input voltage-- Maximum input current30mA ADC resolution16BITConfigurationTable 1 shows how to configure the EM 231 module using the configuration DIP switches. Switches 1, 2, and 3selectthe analog input range. All inputs are set to the same analog input range. In this table, ON is closed, and OFF is open. (SW4 to SW6 should be set to the OFF position)Table 1 EM 231 Configuration Switch Table toselectAnalog Input RangeUnipolarFull-Scale InputResolutionSW1SW2SW3OFFOFFOFF0 to 20mA0.000625mAOFFON4 to 20mA0.0005mAThe EM231 8AI module has different beginning input address in different slot and its address is not in AIW but in VW, you can calculate the address by the following formula, x(VWx) = a × 64 + b × 2 (a is the slot no., and b is the point no.)Table 2 Address for the EM231 8AIVWxPoint0Point1Point2Point3Point4Point5Point6Point7Slot 0VW0VW2VW4VW6VW8VW10VW12VW14Slot 1VW64VW66VW68VW70VW72VW74VW76VW78Slot 2VW128VW130VW132VW134VW136VW138VW140VW142Slot 3VW192VW194VW196VW198VW200VW202VW204VW206Slot 4VW256VW258VW260VW262VW264VW266VW268VW270Slot 5VW320VW322VW324VW326VW328VW330VW332VW334Slot 6VW384VW386VW388VW390VW392VW394VW396VW398Note: Because the offset address of Td2X text display is also in VW0, so If you need to use Td2X text display in your system, please don't put the EM231 8AI×TC module in slot 0,orthe td2X will not work normally. SIEMENS TD200 text displayer is same as TD2X.(SIEMENS is the trademark of SIEMENS AG.)Software Configuration
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product