1/5
33kv 35kv 36kv 38kv Permanent Magnetic Actuator Automatic Circuit Recloser图133kv 35kv 36kv 38kv Permanent Magnetic Actuator Automatic Circuit Recloser图2

33kv 35kv 36kv 38kv Permanent Magnetic Actuator Automatic Circuit Recloser

$3.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: 33kv 35kv 36kv 38kv Permanent Magnetic Actuator Automatic Circuit Recloser Model NO.: AB-3S-40.5 Type: Switch Cabinet Working Ambient Temperature: -50-+70 Creepage Distance: >31mm/Kv Ice-Coverage Thickness: <10mm Wind Speed: <35m/S Trademark: New Concept Transport Package: Wood Specification: 200Kg Origin: Yangzhou HS Code: 8535210000 Product Description 33kv 35kv 36kv 38kv Permanent Magnetic Actuator Automatic Circuit RecloserThe AB-3S series circuit reclosers are recently-developed pole-mounted intelligent vacuum circuit reclosers of a new generation, which absorb the advanced domestic and foreign technologies adopted by our company, embody the design concept of being "intelligent, energy-saving, environemntally-friendly and maintenance-free". This product integrates such functions as control, protection, measurement, fault positioning, online monitoring and synchronous closing. With full functions and high digitalized and intelligent degree, they are top choices for equipment of power distribution network automation and intellectualization process.This product conforms to IEC60044-1, IEC60060, IEC60068-2, IEC60099-4, IEC60255-27, IEC60270, IEC60280.1, IEC60529, IEC60694, IEC60815-1, IEC60870-5-101, IEC61000-4, IEC61243-5, IEC62271, standards, etc.Major Technical Parameters are shown below:Rated voltagekV33Rated currentA1250/1600Rated frequencyHz50/601min power frequency withstand voltage (to earth/open contacts)kV95Rated lightning impulse withstand voltage (to earth/open contacts)kV185Rated short circuit break currentkA25/31.5Rated short circuit making current (peak)kA63/80Thermal stable current(4s)kA25/31.5Dynamic stable current(peak)kA63/80Rated short circuit current break timeTime20Closing timems≤100Opening timems≤70Average open speedm/s1.3~1.8Average close speedm/s1.0~1.7Mechanical timeTime10000Rated operation sequence of circuit breakerO-0.3s-CO-3s-CO-3s-CO-lockoutCurrent transformer ratioOptionalAccuracy degreeOptionalShell protection degreeIP64Weightkg300Our advantages:1. Most parts are manufactured ourselves, like: frame, cabinet, permanent magnet mechanism, insulation part, control panel, etc. That means the process quality control is effectively controlled.2.Adopt fast algorithm with national patent technology (patent number: ZL200720037710.7) so as to obtain fast breaking capacity of circuit breaker. As a result, it can isolate fault circuit rapidly. It takes less than 25ms from inspecting fault to cut fault circuit by separate circuit breaker. It can avoid the problem of override trip effectively. 3.Adopt single phase earthing protection system with national patent technology (patent number: ZL201020178325.6). It can realize on-line judgment to single phase earthing fault of low current earthing system without adding device. Releases warning or tripping action according to setting valueOur service:1. Pre-sale technical support, training;2. On-site factory inspection is accepted;3. Open atitude for cooperation;4. Punctual goods delivery;5. After-sale technical support and service.
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

Recommend product