1/5
12kv 24kv Ring Main Unit Rmu Air Insulated Switchgear图112kv 24kv Ring Main Unit Rmu Air Insulated Switchgear图2

12kv 24kv Ring Main Unit Rmu Air Insulated Switchgear

$1.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: 12kv 24kv Ring Main Unit Rmu Air Insulated Switchgear Model NO.: FM6 Brand: Farady Shell Protection Grade: IP56 Shell Material: Stainless Steel Application Range: High-rise Buildings Size: 1 Uint Operation Voltage: High Voltage Form: Partly-welded Type Certification: ISO9001:2000, VDE, CCC Structure: Fixed Board Type: Distribution Metering Box Name: 12kv 24kv Ring Main Unit Rmu Air Insulated Switchg Rated Voltage: 12/24kv Rated Frequency: 50/60Hz Rated Current: 630A Transport Package: Standard Export Wooden Case Origin: China HS Code: 8535210000 Product Description ++++General12/24/36kv-630A Air/Sf6 Gas Insulation Switch-Gear Type Ring Main UnitFM6 unit type SF6 ring net cabinet with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, FM6 unit type SF6 ring net cabinet can completely meet the requirement of continuously variable market. It can take self-produced FLBS36-36 load switch or SFG type SF6 load switch by ABB; also according to user's demand can be assembled with the internationally top-ranking FGB1 series vacuum circuit breaker with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our VS1-12 type vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of "Four Controls" when matched with FTU and RTU. ++++Service environmenta) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-35ºCb) Humidity: Monthly average humidity 95%; Daily average humidity 90% .c) Altitude above sea level: Maximum installation altitude: 2500md) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.e) No frequent violent shake++++ Main technical specificationsNoItemUnitParameter1Rated voltagekV3640.52Rated frequencyHz50/603Rated currentA630/80041min Power frequency withstand voltagewetkV7095drykV801105Lightning impulse withstand voltagekV1701856Rated short circuit breaking current (peak)kA1952157Rated active load and close circuit breaking currentA400/6308Rated transferring currentA120010009Rated short circuit making current (peak)kA636310Rated cable off loadA5011Transformer off loadA1612Rated withstand current (peak)kA6313Short time withstand current (2s)kA2514Mechanism lifetimes20002000Note: For short circuit breaking and peak current is based on Fuse plus combination.++++Ring Main Unit StructureFM6 type switchgear unit is developed and produced by the company itself according to the requirement of domestic electrical system through absorbing the foreign technology, the main components of which are all the imported original binding.The switchgear has double-fracture, switching on/off and earth switch, reversible contactor,with SF6 as arc extinguishing medium. Reversible contactor lies in the die casting epikote crust that strengthens the structure.Every switch is permanently sealed after charged by SF6 gas, the gas leakage can be detected by helium detector.It is not limited for the vertical or horizontal installation, the typical installation inside the ring main unit is to place a separating steel plate between cable chamber for the horizontal installation, which isolates the bus-bar from cable connector to conform with the most strictsafety requirement for running maintenance.There are a weak point of structure behind the crust, in case inside happens the arcing when the load switch breaks and makes current, it would be pushed open, then the arc leakage valve on the top of cabinet is pushed open to lead the over-pressure gas flow out of cabinet.***Upper UnitSFG LBS with switching on/off and earth switch operating mechanism with mechanical position indicatorcrust of busbar cubicle, integrated low-pressure chamber interlocking device, bus bar, control cable tank.***Lower UnitCrust, current mutual-inductor, earth switch,voltage mutual-inductor, cable bottom plate matched with cable strutting pieces
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product