1/5
![Sjr2-3000 Series Inbuilt Bypass Soft Starter图1](https://www.gongwong.com/file/upload/2020/0405/134/133235571.jpg.middle.jpg)
Sjr2-3000 Series Inbuilt Bypass Soft Starter
$200.00 / Piece
- FOB Price:
- Negotiable | Get Latest Price
- Order Quantity:
- 1 Set / Sets
- Supply Ability:
- 1000 Set / Sets per Month
- Port:
- shanghai
- Payment Terms:
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- Delivery Detail:
- 5 days
Hot in store
Product Details
Product Name: Sjr2-3000 Series Inbuilt Bypass Soft Starter Model NO.: SJR2-3000 Material: Aluminum Alloy Customized: Non-Customized Condition: New Certification: CCC, ISO: 9001, CE Function: Protection Signal: Continuous Mathematical Model: Linear Structure: Combination Task: Adjust Color: Grey Trademark: SANYU Transport Package: Carton, Wooden Box Specification: CE, CCC, SGS, ISO. Origin: China HS Code: 85114099 Product Description SJR2-3000 Series soft starter with inbuilt bypass contactor the soft starter provides complete motor protection functions including start control, running and overloading, phase failure, three-phase unbalance, over-voltage, under-voltage protection and so on with no need to further install bypass contactor and thermal relay, therefore, as another great achievement in the intelligentization of motor protection and networked technology application, it simplifies the circuit, reduces the volume, cuts the cost, makes installation and using more convenient.Power supply: Three-phase AC 380V or 660V± 15%, 50 Hz or 60 Hz commercial power, private power station or diesel generator set, the power capacity must meet the soft starter's starting requirements on motor.Applicable motor: Three phase squirrel-cage asynchronous motor, the rated power of the motor should match that of the soft starter.Start frequency: No requirements, the specific frequency shall be depended on the loading.ClassificationTerminal markingTerminal descriptionFunction descriptionConnection point output01, 02Power input01, 02 are AC220V power input to the control panel03, 04Running output (delay)03, 04 are programmable relay output, the delay time is set by the code F4 while the output function time is set by code FE.05, 06Fault output005, 06 are fault relay output, they will be on when there's fault with the soft starter or the power is cut off and be off when the power is on. (capacity of the connection point AC250V/3A)Connection point input07Instantaneous stop inputThe motor will stop immediately when 07 and 10 are disconnected (or be tandemly connected to the normally closed point of the thermal relay)08Soft stop inputThe motor will slow down for soft stop when 08 and 10 are disconnected (or automatically stop).09Start inputThe motor will start for running when 09 and 10 are connected.10Common terminalCommon terminal for signal input of the connection pointsAnalog output11, 12Analog output11 and 12 are 4~20Ma DC analog output which are used to monitor the current of the motor in real time. The maximum value 20mA indicates the current of the motor is four times of the nominal current of the soft starter.4~20Ma DC meter can be connected for observation. Maximum load resistance of this output is 300Ω.CommunicationDBRS485communication input/outputInput and output signal terminal of RS485 communication, can be used to connect several soft starters.Certification we have
Contact with Supplier
Recommend product