1/5
Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposin图1Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposin图2

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposin

$1.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT Model NO.: CP-4 Voltage Transformation Principle: Electromagnetic Type Magnetic Circuit Structure: Single Stage Type Installation: Active Type Insulating Medium: Insulating Paper Winding Form: Multilayer Honeycomb Type Usage: Measurement Operation Condition: Indoor Phase: Single Type: Current Transformer Application: Electronic Model: Cp4 Series Current Transformer 13mm Is_Customized: Yes Trademark: HEYI Transport Package: Foam Box Specification: CE, ISO, Rohs Origin: China HS Code: 8504311000 Product Description CP4 Encapsulated Interposing Current TransformerEncapsulated current transformerTough resilient flame retardant UL-94V0Temperature range -20°C to 70°CAccuracy class 1.0 ,0.5Test voltage 4kV 50Hz 1minIEC44-1,IEC185,BS3938,DIN42600Insulation Class E,Max 120°CTotally enclosed in tough,self extinguishing mouldingsOperating voltage 0.72kVSummation current transformerNormal secondary winding 1A or 5AIntroductionThere are C.Ts.Which are interposed between the main C.T.and the burden(Load)so that the secondary current of the main C.T. is adjusted as required by the burden.When used in providing transformer differential protection,these C.Ts are also used to correct the phase shift,which may result due to particular method of connection used for the transformerwindings.The main fuction of an interposing CT is to balance the current supplied to the relay or others where threre would otherwise be an imbalance due to the ratios of the main CTs.Interposing CTs are equipment with a ratio that can be selected by the user to achieve the balance required.As the name suggests,an interposing CT is installed betweenthe secondary winding of the main CT and relay.They can be used on the primary side or secondary side of power transformer being protected,or both interposing CTs also provide a convenient method of establishing a delta connection for the elimination of zero sequence currents where this is necessary.Compliance:IEC 185 and BS 3938/1973Burden:5VA or 7.5VAAccuracy:0.5 or 1.0Rated voltage:720V 50/60HzDielectric voltage:4kVType of material:High impact flame-retardant moulded resinInput:5/5A,1/1A other by request.A When the main C.T.s having rated secondary current of 1Amp.And the burden requires a rated current of 5Amp,an I.C.T.is used,at the load end so that the lead burden is fed by 1Amp.Current.The lead burden on the I.C.T.is negligible as it placed very close to the burden(Pic.1)B The arrangement suggested in a above may also be used when the main C.T.is having rated secondary of 5Amps.And the burden requires a rated current of 1amp.In this case .However,the I.CT, of ratio 5/1 Amp will have to be placed at the main C.T.end to reduce the effect of lead burden on the main C.T.(Pic. 2)C In the case of transformer differential protection when the main C.T. ratios do not match.If phase shift is introduced due to the model of connections of the transformer on the H.T. and L.T.side,I.C. Ts Can be used to correct the phase shift.It is assumed here that all main C.Ts are star connected(Pic.3)D For suppressing zero sequence currents from the out of balance current.This is achieved by providing an additional secondary winding on I.C.Ts.Which is connected in closed delta(Pic.4)E If high ratio is selected for the main C.T. against a low load current,I.C.Ts may be used across the main C.T. to reduce the ratio effectively and satisfactorily cater ti the rated current requirement of the burden(Pic.5)In all above applications it must be borne in mind that an I.C.T. imposes burden on the main C.T.if this burden is required to be restricted to a certain value,the value must be specific to enable the manufacture to design the I.C.T.suitably.If this value of burden(expressed in VA)is too low,it may result into an uneconomical design of the I.C.T.
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

Recommend product