1/5

Hact Clamp-on Split Core Current Transformer for Energy Monitoring Applications 300A/100mA Current C
$1.00 / Piece
- FOB Price:
- Negotiable | Get Latest Price
- Order Quantity:
- 1 Set / Sets
- Supply Ability:
- 1000 Set / Sets per Month
- Port:
- shanghai
- Payment Terms:
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- Delivery Detail:
- 5 days
Hot in store
Product Details
Product Name: Hact Clamp-on Split Core Current Transformer for Energy Monitoring Applications 300A/100mA Current Converter 400A/40mA 500A/50mA 600A/60mA 600A/333mv Model NO.: HACT Voltage Transformation Principle: Capacitive Type Magnetic Circuit Structure: Single Stage Type Installation: Active Type Insulating Medium: Insulating Paper Winding Form: Multilayer Honeycomb Type Usage: Protection, Measurement Operation Condition: Indoor Phase: Single Type: Current Transformer Application: Electronic, Instrument Model: Hact Clamp-on Current Transformer Window Size: 43*33 Mm Rated Current: 200A Frequency: 20Hz-400Hz 6ft Twisted Pair Wire Leads: #22 AWG(Black and White)...Optional Accuracy: Class 1.0 Linearity: +-1% Rated Accuracy Range: 10%-120% of Rated Current Is_Customized: Yes International Courier: DHL(40% Discount) Trademark: HEYI Transport Package: Export Foam Box Specification: CE, ISO, Rohs Origin: Liushi, Yueqing, Zhejiang Province, China HS Code: 8504311000 Product Description HACT split core current transformerprovides precision messurement for energy monitoring applications to sensingpowerloading equipment without interrupting the lines. It has been specifically designed to be easy to open and yet maintaintheaccuracy required for intelligent meter, quick to fit around cables.Features 1) Reliable locking mechanism, safe, easy to install, portable.2) Clamp On ergonomic design3) Precision measurement and low phase shift4)Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs5) easy to open and yet maintain the accuracy required for intelligent meter, quick to fit around cables.Specification Model HACTCurrent Ratio300A/100mA400A/40mA500A50mA600A/60mA300-600A/0.333VPrimary Current (A)300A400A500A600A300-600AMax. Current (A)360A480A600A720A720AOutput100mA40mA50mA60mA0.333VLoad Resistance (Ω)50Ω50Ω50Ω50Ω/Turns Ration3000:110000:110000:110000:1/Class0.5/1.0Protection Level7.5V0-PInsuliation CategoryCATIIIOperating Condition-20ºC~ +50ºC,≤85%RH, No condensation, IN-house & Any direction installableStorage Condition-30ºC~ +50ºC,≤85%RH, No condensationNote: The Current Ratio above are common type, that's ok to customise the ration according tocustomers' requirement.GraphApplications 1) Current measurement, monitoring and protection for electrical wiring and equipment.2) Current and power measurement for electric motors, lighting, air compressor, heatingand ventilation system, air-condition equipment and automation - control system.3) Current, power and energy monitoring device.4) Relay protection device. The advantages of HACT Lead Wire is thick and good quality that meets UL1015 22AWG 600V 105°c (L=600mm).And we have 5 wireconnectors, suchasWires plugs, Audio plugs, Power plugs and so on.How to Order?1. Please let us know what kind of model, color, poles and rated current etc.2. Proforma invoice (PI) will be sent to you.3. Please check and confirm the PI.4. once we confirmed the order, please pay it soon.5. After full payment, all goods will be sent to you in 6-10 days as usual.6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders.Shipping:1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).2. We Provide Drop shipping Service.3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.4. In order to ensure you receive your order tax free upon import, we declare lower value.5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country.Payment:1. We accept Western Union and T/T2.30% deposit and 70% before shipping3. No payment collection. We only can deliver goods after getting full payment.Warranty:1. We provide 1 year warranty.2. If the product is defective, please notify us within 3 days of delivery.3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goodsOur Commitment: BETTER PRICE than other suppliersfor you because of Factory Direct Sale;BETTER QUALITY than beforecaused by our 10+ years experience about CT;STOCK IN TRADE awlaysown to our Fast & Professional production line;FAST DELIVERY as awlaysmade by our GROUP's Enthusiam;TIMING REPLY in 24 hoursall about our TEAM's Passion & Patience.FAQ:1) What is the difference between a moulded case current transformer and a split core current transformer?A moulded case current transformer is a solid ring of steel in a plastic or resin case and can only be used when you fit the cable through the hole in the middle of the plastic/resin case.A split core current transformer is manufactured with the steel core in two pieces. This enables the core to be separated, allowing you to fit the cores around the cable without disconnecting the cables. The disadvantage with split core current transformers is that they can be larger than standard moulded case and the price is approximately four times more expensive.2)Which way round do the Current Transformers go?The current transformers must be fitted and connected in the correct way or the meter will not be accurate. The current transformers are marked on two sides: 'P1' and 'P2.' 'P1' must face the mains side and 'P2' must face the load side. 'S1' must be connected to the main side of the meter and 'S2' to the load side. Refer to appropriate wiring diagram of the meter for correct connections.3)Can the current transformers be a higher or lower ratio then my maximum load?The current transformers should ideally be about 80% of the normal running load, thus allowing a 20% allowance of increasing the load in the future.Contact us:Send your Inquiry Details in the Below,Click"Send"Now!YOUR BENEFITS IS OUR BUSINESS!!!
Contact with Supplier
Recommend product