1/5
DC to AC Power Inverter PV DC1000V Voltage Input Solar Grid Inverter图1DC to AC Power Inverter PV DC1000V Voltage Input Solar Grid Inverter图2

DC to AC Power Inverter PV DC1000V Voltage Input Solar Grid Inverter

$600.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: DC to AC Power Inverter PV DC1000V Voltage Input Solar Grid Inverter Model NO.: LS1000H Nature of Wave String: Square Wave Inverter Circuit Topologies: Full-Bridge Type Power Source: Solar Power Type: DC/AC Inverters Brand: Litto/OEM Certification: SAA, CE, ROHS, ISO9001 Output Power: >1000W Phase: Single Nature of Source Flow: Passive inverter Model Number: Suntree Output Voltage: 360-440 Types: DC/AC Inverters Output Type: Triple, 3pH+N+PE Input Voltage: 1000V DC Output Frequency: 50/60Hz Output Current: 30A Efficiency: 98-99% Operating Temperature Range: -25~60 Short Circuit Production: Yes Trademark: SUNTREE/LITTO/OEM Transport Package: Standard Specification: ce saa Origin: Shenzhen HS Code: 8536620000 Product Description dc to ac power inverter PV DC1000V voltage input solar grid inverterLeading - edgeDouble MPPT Tracker, MPPT tracking accuracy more than 99.8%Max. Efficiency 97.8%, European Efficiency 97.2%Internal DC Switch for added safety protectionPower factor continuously adjustableFlexible communication connection, support USB, WiFi, EthernetSupport online Update from USB or Ethernet5 years standard warrantyComply with European, Asia-Pacific safety regulationsTransformerless design and high power density, offer lighter and more convenient installationHighperformance string inverters Form 3.0kW to 5.0kW Wide PV input voltage range Rapid MPPT tracking technology Two MPPT trackers Superior PV energy harvest Transformerless design with higher operation efficiency Excellent thermal performance High overload capability under most ambient conditionsFull data display and communications LCD display energy data Bright LED indicators imply system status at a glance PC software for remote monitoring and system troubleshooting Interated RS232 and RS485 serial communicationsCost advantages Transformerless design cutting down the cost Light weight and small dimension,reducing shipping cost IP65 protection degree, suitable for outdoor installation,reducing construction cost Low maintenance expenseEasy and affordable to install Light weight and compact size Includes a lightweight portable bracket simplifying installaton Firm IP65 inverter enclosure allows outdoor applicationTechnical speciticationsDATA SHEETLS 3000HLS 4000HLS 5000HINPUT DATA (DC)Max. recommended PV power3150W4200W5260WMax. PV power of per MPPT3150W4200W5260WMax. DC voltage500V500V500VStart voltage100V100V100VPV voltage range70-500V70-500V70-500VMPP work voltage range / nominal voltage100-500V/360V100-500V/360V100-500V/360VFull load dc voltage range150-450V200-450V250-450VMax. input current23.0A23.0A23.0AMax. input current per stringof tracker A/tracker B23.0A23.0A23.0ANumber of independent MPPtrackers/strings per MPP tracker1/21/21/2OUTPUT (AC)Rated AC output power3000W4000W4960WMax. AC apparent power3000VA4000VA5000VAMax. output current15.0A20.0A25.0AAC nominal voltage; range220V/230V/240V 180-280Vac220V/230V/240V 180-280Vac220V/230V/240V 180-280VacAC grid frequency; range50Hz, 60Hz; ± 5Hz50Hz, 60Hz; ± 5Hz50Hz, 60Hz; ± 5HzPower factor0.90 capacitive..0.90inductive0.90 capacitive-.0.90inductive0.90 capacitive..0.90inductiveTHDIless than3%(at nominal output power)less than3%(at nominal output power)less than3%(at nominal output power)AC grid connection typeSingle phaseSingle phaseSingle phaseefficiencyMax. efficiency97.5%97.5%97.6%Euro-eta96.6%96.6%96.7%MPPT efficiency99.9%99.9%99.9%Protection DEVICESDC reverse polarity protectionyesyesyesDC switch for each MPPToptoptoptOutput over current protectionyesyesyesOutput overvoltage protection-varistoryesyesyesGround fault monitoringyesyesyesGrid monitoringyesyesyesIntegrated all-pole sensitiveLeakage current monitoring unityesyesyesGENERAL DATADimensions (W/H/D)355*395*170mm355*395*170mm355*395*170mmWeight16.5KG17KG17KGOperating temperature range-25°C to 60°C-25°C to 60°C-25°C to 60°CNoise emission(typical)25dB(A)25dB(A)25dB(A)Altitude2000m without derating2000m without derating2000m without deratingSelf-Consumption(night)less than 0.5Wless than 0.5Wless than 0.5WTopologyTransformerlessTransformerlessTransformerlessCooling conceptNaturalNaturalNaturalEnvironmental Protection RatingIP65IP65IP65Relative Humidity100%100%100%FEATURESDC connectionH4/MC4H4/MC4H4/MC4AC connectionConnectorConnectorConnectorDisplayLCD. LEDLCD. LEDLCD. LEDInterfaces:USB/Wi-Fi/GPRS/RS485yes/yes/opt/optyes/yes/opt/optyes/yes/opt/optWarranty: 5 years/ 10 yearsyes/optyes/optyes/optCERTIFICATE AND APPROVALSCE, VDE 0126-1-1, IEC 62109, G83-2, G59-3, AS4777, AS/NZS 3100, VDE-AR-N4105, EN50438, EN62116, CQC, MEA, PEA, IEC61683Suntree series string solar three phase inverterCompact size and high power density High speed MPPT for real time power tracking and improved energy harvesting Transformerless operation for highest efficiency 98.2% High overload capability under most ambient conditions Certified grid connected operation according to the international standards True three phase sine wave output Integrated RS485/RS232 serial communications Multi-language friendly LCD display Easy maintenance cooling fansMODEL(LT)5000HD6000HD8000HD10000HD12000HD15000HD17000HD20000HD30000HDMax. DC Input Power(W)550066009000115001330017000190002200033000Max DC Voltage(Vdc)9001000MPPT Operating Range(Vdc)250~720250~800Number of Parallel Inputs24610Number of MPPT Trackers2Max.Input Power per MPPT35004000500060007000850095001100016500Max. Input Current(A)2*102*122*162*222*242*302*322*352*41Nominal Output Power(W)500060008000100001200015000170002000030000Max. Output Power(W)500060008000100001200015000170002000030000Nominal Output Current(A)7.38.711.614.517.421.724.62943.5Max. Output Current(A)7.99.512.716.219.424.327.532.348Nominal AC Output Voltage(Vac)400AC Output voltage range (Vac)*360~440AC Grid frequency range (Hz)*50/60±5Power Factor (cosφ)0.9(leading)~0.9(lagging)THDI<3%(at nominal power output)Max.efficiency97.6%97.8%98.1%98.1%98.1%98.1%98.1%98.2%98.1%Euro.efficiency96.7%96.9%97.3%97.5%97.6%97.5%97.6%97.6%97.5%MPPT. efficiency99.6%99.6%99.6%99.6%99.6%99.6%99.6%99.6%99.6%Operating Temperature(ºC)-25~+60Noise typical[dB(A)]<25<50<65Operating Consumption(W)0Electrical IsolationTransformerlessCooling ConceptNatural CoolingFan Cooling(IP54)Protect LevelIP65LCD Screen: Display the operating data and situations, warning/error codes and information.The model of inverter (for example, 10000TL)ALARM LED: Indicates the alarm of inverter.POWER LED: Indicates the inverter is running normally.Fault LED: Indicates the fault of inverter.Function Key: Used to set different parameter and display language for the inverter.Description of inverterCommunicationRS485/RS232(WIFI Optional)Dimension (W×D×H)(mm)470*165*560470*165*585470*165*670580*235*800Weight (Kg)32355065Opening the packageAfter opening the package, please check the contents of the box. It should contain the following accessories:ItemNameQuantity1.Solar inverter1pcs2.Mounting frame1pcs3.Mounting screws and blocks9pcs4.Safety-lock screws4pcs5.Socket head wrench1pcs6.DC socket assembly1set7.Special RS-232 cable1pcs8.Instruction manual1pcs9.Monitor software(CD)1pcs10.Warranty sheet1pcsLCD Screen: Display the operating data and situations, warning/error codes and information.The model of inverter (for example,Suntree 10000TL)ALARM LED: Indicates the alarm of inverter.POWER LED: Indicates the inverter is running normally.Fault LED: Indicates the fault of inverter.Function Key: Used to set different parameter and display language for the inverter.Description of inverterLED indicatorsInformation ListGreen LEDYellow LEDRed LEDWait StateFLASHOFFOFFFault RevoverOFFonOFFNormal StateonOFFOFFFault StateOFFOFFonPermanent StateonOFFOFFWait State: Inverter is waiting to Check State until the end of reconnection time. In this state,the PV voltage is more than 250V and grid voltage value is between the max and min limit; Otherwise,Inverter will go to Fault State or Permanent State.Fault Revover: Inverter is in the process of circulating in take place mistake or breakdown,break down Inverter to re- combine a net after the reliefNormal State: Inverter feeds to grid energy from PV panel as much as possible according MPP trackers.Inverter will go to FaultState or PermernentState if any error or fault occurs.Fault State: Inverter has occurred some recoverable errorPermanent State: Inverter has occurred some unrecoverable error. It will stay in Permenent State.You should take some measure according the error code.3.2 Operate the Function KeyTo view the operating data of the inverter, you can press the Function Key.Of course, the data also will automatically and periodically display.To set different display contrast and display language for the inverter,please carefully refert to the following chart.Step 1: Ensure that the AC cable and DC cable is connected correctly, unused DC plugs and AC terminal cover are sealed.Step 2: Connect the DC and AC switches. The inverter starts up automatically when DC-power from the PV strings is sufficient.once the solar inverter starts, it enters one of the following 3 states in turn:Standby: The PV string can only provide just enough voltage to minimum requirements of the internal controller unit.Waiting: When the PV string DC voltage is greater than 200V, The inverter enters a "waiting" state and attempts to connect to the grid.Normal: When PV string DC voltage is greater than 300V, Inverter operates in the normal state.The Inverter will keep MPPT function and deliver power to AC Grid when it is in normal operation.Maybe it will stop under the situation of low input DC-power,Don't worry, it will automatically restart again when DC-power from the PV string is sufficient.Error or Warning statusInverter is designed to be user-friendly, therefore, the error or warning status of the Inverter can be easily understood by reading the information shown on the front panel display. All possible messages are shown in the following table.DISPLAYCOMMENTSSystem fault1Auto Test FailedAuto Test does not pass2No UtilityNo Grid Connect3PV Over VoltagePV panel Voltage is too high4Isolation FaultInsulation Problem of PV panel5GFCI Faultleakage current is too high6Grid Freq. FaultGrid frequency is out of range7Grid Volt. FaultGrid voltage is out of rangeInverter fault1Consistent FaultConsistent Fault2Over Temp. FaultInternal temperature abnormal3Relay FaultOutput relay Fault4DCI Out RangeOutput Current DC Offset too high5REEPROM FailEEPROM Fault6Comm. LostCommunication Fault7Bus Over VoltageDC Bus over-voltage8Bus Low VoltageDC Bus under-voltage9Boost FaultBoost Current or Voltage Fault10GFCI Device FaultGFCI Device is damaged11Inv. Curr. OverInverter output current too high12Fan LockFan Lock13RTC FailReal Time Clock IC Fault14SCI FaultCommunication FaultWarranty Claim Procedure:Please report defective devices with a brief error description to the SUNTREE distributors.If we agree to a replacement, we generally send an equivalent replacement device according to modeland age, the remainder of the warranty entitlement will be transferred to the replacement device. In this case,you do not receive a new certificate since your entitlement is documented at SUNTREE.The replacement will be packaged appropriately for transport and shipped out within 2 working days.The defective device is to be packed in this transport packaging for return transport to the distributor.If the on-site service of re-installation is necessary,the end customers need to negotiate with the distributors in advance.All warranty services in warranty period are free of charge.ph//:008615067704943
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

Recommend product