1/5
DC Hysteresisgraph Soft Magnet Measurement图1DC Hysteresisgraph Soft Magnet Measurement图2

DC Hysteresisgraph Soft Magnet Measurement

$35.00 / Set
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: DC Hysteresisgraph Soft Magnet Measurement Model NO.: 201SD Trademark: TJ Transport Package: Wooden Carton Origin: China HS Code: 9031803100 Product Description 201SD automatically measure the Magnetizing Curve and Hysteresis Loop of the soft magnets under static(DC) condition. Precisely measure and show static magnetic characteristics, such as initial permeability(μi), max permeability(μm), saturated flux density(Bs), remanence(Br), coercivity(Hc) and hysteresis loss. According to the classic ballistic method principle, 2010SD combines the computer control and A/D,D/A, replace the conventional ballistic galvanometer with electronic integrator, achieve the analog ballistic measurement under microprocessor. It completely removes the non-instant error and is more accurate, faster and with a good repeatability. It removes various kind of artificial factors, offers a stable basis to study the magnetizing progress.Applied StandardsGB/T 13012-2008 Soft magnet static(DC) hysteresisgraph measurementGB3656-83 Pure iron for electrical grade measurementGB3657-83 Soft magnetic alloy DC measurementGJB 937-90 Soft magnet permeability measurementIEC 60404-4 Soft magnet static(DC) hysteresisgraph measurementIEC 60404-7 Coercivity measurement in opened magnetic circuitMeasured ParametersInitial permeability (μi)Max permeability (μm)Saturated flux density (Bs)Remanence (Br)Coercivity (Hc)Hysteresis loss (Pu)B(H) magnetization curveB(H) hysteresis loopµ(H) permeability curveMain Features1. Apply to: soft magnetic ferrites, permalloy, amorphous, nanocrystalline, iron dust core, electrical pure iron and silicon steel etc.2. Sample shape: ring, toroid, E and U closed circuit.3. Closed circuit samples directly winded: samples, magnetized coils(N1), measuring coil(N2) form a non-load transformer.4. Measure open-circuit samples need fixtures(solenoid or permeameter optional), its inner field is measured by a built-in magnetic potentiometer(optional).5. Measure the field strength through testing the magnetizing current, field locking accuracy up to 0.1%.6. Measure the flux density by electrical integrator, the integrator ZERO drift self-correcting by software.7. Measuring method: analog ballistic and magnetic field sweep.8. Adopt analog ballistic method to measure basic magnetization curve, can accurately measure magnetic characteristic parameters on magnetization curve: μi, μm, Bs, value μ of any point. 9. Adopt analog ballistic method and magnetic field sweep to measure saturation hysteresis loop, can accurately measure magnetic characteristic parameters on hysteresis loop: Bs, Br, Hc and Pu. (This method is only used by linkjoin, highly approved the accuracy)10. Automatic demagnetizing function before μi test, demagnetizing with saturated AC 10Hz.11. Select to test single parameter with analog ballistic method to save time, the time of every testing point can be set from 0.1 second to 0.9 second.12. Adopt the B speed feedback, it can automatic regulate the density with the shape of sample magnetic characteristic curve, and curve can also be tested according to the testing point predefined by users.Software Functions1. Operate under Windows7, complied to Windows software restricts, easy to operate.2. Automatic control, intelligent judgment, without manual operation all through the progress.3. Sampling waveform and instrument status under real-time monitoring, and can be stopped at any time.4. The effective sectional area and length of magnetic path of samples can be calculated according to the overall dimension of samples.5. Automatic detecting sample condition, facilitate users to test unknown samples.6. System adopts database format, can directly print or output test result to Excel form.7. Various file management functions: data saving and deleting, remove all the data etc. 8. Data files contain complete sampled data, sample parameters, instrument parameters and testing schemes, adopt text format, can be conveniently typed into other software.9. Display B(H) magnetization curve, B(H) magnetic hysteresis loop or μ(H) permeability curve, and can display coordinate information of every data point on curve.10. Support various kinds of printers, test report accurately match printer sheet. Print preview function, it can conveniently regulate the size and edge distance of test report. Test report can be directly printed, or generate JPG image file.11. JPG image file can be sent directly through E-mail, or saved into disk.12. Test reports contain complete curve diagrams, test results, test conditions and sample parameters, both Chinese and English format can be adopted to facilitate adding user mark and enterprise name.13. Multiple unit system optional to satisfy the application habits of different users.Technical ParametersMeasure standard ring sample (ferrite), reports as following,ParametersBs(%)Br(%)Hc(%)Pu(%)μm(%)μi (%)Uncertainty(k=2)111.5125Repeatability± 0.5± 0.5± 0.5± 0.5± 1± 3Hardware Parameters201SD/K50 Hysteresisgraph201SD/K75 HysteresisgraphOutput Voltage: 0~±50VOutput Current: 1mA~10A,13 auto-rangesCurrent Fineness:< 0.1%×current rangeCurrent Stability: better than 0.05%Flux Range: 0.25, 0.5, 1, 2, 5, 10, 20 mWbFluxmeter Sensitivity: 0.05μWb(ballistic) 0.1μWb(sweep)Output Voltage: 0~±35VOutput Current: 1mA~20A,13 auto-rangesCurrent Fineness:< 0.1%×current rangeCurrent Stability: better than 0.05%Flux Range: 0.25, 0.5, 1, 2, 5, 10, 20 mWbFluxmeter Sensitivity: 0.05μWb(ballistic) 0.1μWb(sweep)PC6616 A/D CardA/D convert : 16Bit,8channels differential inputConvert period : < 10μsConvert accuracy : 0.02%(full range)D/A convert : 16Bit,2channels outputConvert accuracy : 0.1%(full range)IPC (ADVANTECH IPC-510)PrinterMain Board: G41, 5PCI slot, 2*RS-232CPU: E5300 dicaryon 2.6GRAM: DDR3 1333, 2GHard disk: Seagate500G,SATA,16MOperating system: Windows XP or Windows 7Type: Laser printerMax print size:A4Print speed: reach to 18ppmMax resolution: 1200x1200dpiConsumables: cartridge and powder togetherCapacity of carton: 150pcs, ordinary paperConfigurationSerial No.Product NameModelQua.UnitRemarks1Hysteresisgraph201SD1set2Data Acquisition CardPC6616(Insert in computer)1pieceInstall in computer3Measurement SoftwareSMTest (Install in computer)1set4ComputerAdvantech IPC1setWith 18.5 inch monitor5PrinterHP1108 laser printer1setBlank laser printer6Standard SpecimenRing1piece7Cabinet1setCAUTION:As the products of our company are in constant updates, the change of products without pre-notice.AccessoriesModelStandard SolenoidClass A PermeameterCustomized PermeameterTest EquipmentEnvironment Temperature23ºC5±ºCHumidity<65%Length50cmCustomized according to requirementsCustomized according to requirementsMax magnetic field30kA/m120kA/m30kA/mSpecimens typeStrip, rod, and sheetStrip, rod, and sheetStrip, rod, and sheetSpecimens sizeL/D ratio>1:20Length>250mmDiameter 4mm, Length 50mmMeasured parametersRelative permeability ur of weak magnetic materialsSaturation magnetic induction BsSaturation magnetic induction BsPlease contact us for more about the products.......
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

Recommend product