1/5
Air to Water Low Temperature Evi Heat Pump图1Air to Water Low Temperature Evi Heat Pump图2

Air to Water Low Temperature Evi Heat Pump

$800.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Air to Water Low Temperature Evi Heat Pump Model NO.: ESSA Series Heat Source Type: Air Source Heat Pump Working Medium: R407c, R410A Certification: ISO9001, CE Compressor: Emerson Copeland Evi Series Throttle Unit: Electric Expansion Valve Warranty: 2 Years, 18 Months, 1 Year DC Inverter: Optional Housing Material: Galvanized Steel Working Ambient Termp.: -25deg C~43deg C Structure: Monoblock Type Refrigerant: R407c, R410A(Optional) Air Side Heat Exchanger: Blue Aluminum Fin Arround Copper Tube Power Supply: 50Hz, 60Hz(Optional) Water Side Heat Exchanger: Tube in Shell Type/Plate Type(Optional) OEM/ODM: Available Overseas Service: Available Power Source: Electric Application: Cooling and Heating Trademark: ESACIR Transport Package: Standard Export Package Specification: CE Origin: Guangdong, China HS Code: 8418692090 Product Description 1.Application of Air Source Heat Pump--Eurostars EVI air source heat pumps are designed for house heating and cooling. User can change the working mode by operating the controller. Compressor starts/stops according to return water temperature. When all rooms reach preset temperature by room thermostat, heat pump will be turned off through linkage switch.--Wide Range of Applications: these EVI low temperature heat pumps could meet the heating and cooling requirements of different places, such as villas, houses, schools, factories, hotels, hospitals, spa centers, sauna centers, greenhouses, flower gardens, farms, etc.2.Eurostars Air Source Heat Pump Features:1) EVI compressor special designed for high COP (Coefficient of Performance): 4.0 even in bad weather condition or area. 2) base frame and external panels made of galvanized powder coated steel 3) Water exchanger equipped with high efficiency tube in shell heat exchanger 4) Reliable compressor with R407C/R410A refrigerant 5) Stable water flow switch &backflow proof. 6) Fully sealed control box with water proof level IPX4 7) Intelligent microprocessor control systems 8) Air exchanger (fin-coil) with hydrophilic coating 9) Thermostatic heating element for evaporator, anti-frosting10)Every capillary tube of SANHUA/DANFOSS/EMERSON expansion valve full-covered by silicon/soft pipe refucing buffer friction, subtle vibration from compressor/fan, keeping strong as 15-20 years working life, even longer. 11)No need of auxiliary electrical heating and works well even at -25 ºC~30 ºC. 12) Lowest noise that fan motor &Copeland high efficient compressor, thermostability PE material with bond for soundproof &heat preservation. 3. Air Source Heat Pump Technical DataAir Source Heat Pump Unit(EVI Low Ambient Temp.Type) (Heating&Cooling)ModelESSA-05LHNESSA-05LHNESSA-05LHNESSA-05LHN2.5ES3ES4.5ES5ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ220V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)7.68.414.015.2Input power(kW)2.322.584.384.75Current(A)11.14.721.08.7COP(W/W)3.283.263.203.20Water flow(m3/h)1.71.93.13.4Air: -10ºC/,Water In/outlet:40ºC/45ºCHeating capacity (kW)5.325.889.810.64Input power(kW)2.202.454.164.51COP(W/W)2.412.402.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)4.04.47.48.0Input power(kW)2.092.333.954.29COP(W/W)1.911.891.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)3.94.26.47Input power(kW)2.352.524.404.30COP(W/W)1.661.671.451.63CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)6.87.612.613.7Input power (kW)2.392.664.514.89Current (A)11.44.821.68.9COP(W/W)2.862.842.792.80Water flow (m3/H)1.51.72.83.1ModelESSA-10LHNESSA-10LHNESSA-10LHNESSA-15LHN5.5ES7ES2*5ES2*7ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)17.519.030.440.8Input power(kW)5.465.949.512.75Current(A)26.110.817.323.2COP(W/W)3.23.23.23.2Water flow(m3/h)3.94.26.89.1Air: -10ºC/,Water In/outlet:40ºC/45ºCHeating capacity (kW)12.2513.321.2828.56Input power(kW)5.195.649.0312.11COP(W/W)2.362.362.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)9.210.016.021.4Input power(kW)4.935.368.5711.51COP(W/W)1.861.861.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)7.591419Input power(kW)5.105.808.6012.00COP(W/W)1.471.551.631.58CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)15.817.127.436.7Input power (kW)5.626.129.7913.13Current (A)26.911.217.823.9COP(W/W)2.802.792.802.80Water flow (m3/H)3.53.86.18.2ModelESSA-20LHNESSA-30LHNESSA-40LHN4*5ES4*7ES4*9ESWorking modeHeating&CoolingPower supply380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)60.076.0115Input power(kW)18.723.7635.9Current(A)34.143.365.5COP(W/W)3.213.203.20Water flow(m3/h)13.417.025.7Air: -10ºC/,Water In/outlet:40ºC/45ºCHeating capacity (kW)4253.280.5Input power(kW)17.7722.5734.11Current(A)2.362.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)31.539.960.4Input power(kW)16.8821.4432.40Current(A)1.871.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)2838Input power(kW)17.2024.00Current(A)1.631.58CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)54.068.4103.5Input power (kW)19.2624.4736.98Current (A)35.144.667.4COP(W/W)2.802.792.80Water flow (m3/H)12.115.323.14.Air Source Heat Pump Main Components IntroductionNoNameDescription1CompressorBrand: Copeland/Panasonic2Air Heat exchangerHydrophilic Aluminum foil and copper pipe with inner thread heat exchanger3Water Heat exchangerType: Tube in shell, advantage: thick copper pipe, strong quality. Big diameter of water flow: small water resistance. Thread coil: large heat exchanging surface4Expansion valveBrand: Danfoss/Sanhua or other brand, Type: Electronic type5Four way valveBrand: SANHUA, most famous in China6FanBlade: low noise and large air flow. Motor: Axial type, stable and large air flow7AC contactorBrand: EATON/FUJI/Schneider,etc, smart action, stable quality8ControllerLCD screen, multi protections, remote control, simple operating5.EUROSTARS Heat Pump Range:(1) Water source heat pump(2) Geothermal source heat pump(3) Air source heat pump, including swimming pool heat pump(4) EVI air source heat pump(5) Split heat pump(6) DC Inverter heat pump6.about USWe, EUROSTARS, which established in year 2006, is amodern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.Webiste 1: http://www.eurostarschina.com/Website 2: http://www.waterchiller-unit.com/Instagram: https://www.instagram.com/eurostars_aircon_refrigerationFacebook: https://www.facebook.com/pg/EurostarsHVACRYoutube https://www.youtube.com/channel/UCFwKOPvrf0xSZdOzX0pB52A7.FAQQ:Compared with other products, what's the advantage of Eurostars heat pumps?a. High heating efficiencyb. Low cost: compared with the fuel or gas furnace, the heat pump can save 70% of the energy.c. Environmental protection: there is no emission resulting from burning. The refrigerant for the heat pump is environmentally-friendly refrigerant such as R410A, R407C, R134A which will not destroy the ozonosphere.d. Safety: the operation of the heat pump is safe and automatic.e. Provide OEM/ODM serviceQ:Why it can work at -25ºC?Because of the Enhanced Vapor Injection (EVI) technology from Copeland compressor, EUROSTARS designed EVI gas piping system and controlling system, make EVI air source heat pump can work stably in the low temperature condition.8.Customer visit us9.Air source heat pump delivery or container loading10.Installation instruction or installation photo, project photosA,Place selection of installation Heat pump1). Heat pump should be installed in alarge space, and have good air flow condition.2). Air inlet and outlet must be aclear road, the distance from barrier to inlet and outlet must be longer than 2m.3). Set drain ditch or drain outlet, so that can drain water easily.4). The installation base or bracket must be firm, make sure heat pump work balancely.5). Make sure heat pump is vertical, can't be slanted.6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.7). The installation place can't be near inflammable, flammable thing or fire.8). Installation:---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.---The design of installation base can be according to heat pump weight.---The heat pump bottom should be fixed by bolt.B,Pipe connectionThe drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.C,Water pipe system installationWater pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.There can't be leaking at any place of pipe.After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is clean. After confirm there is not any problem, then insulate all hot water pipes.D,Power supply wiring220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, AB Cconnects live line, Nconnects null line, Econnect earth. Be sure not to connect Nline to live line of power supply.1).When repairing, please turn power supply at "off" side.2).Power supply connecting process:make sure aequipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.Power supply demand:220V rated voltage±10%380V rated voltage±10%frequency:50Hz rated frequency±2%3).if power supply fluctuation is out of demand, please don't start your heat pump.
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

Recommend product