1/5
Air Cooled Water Chiller with Heat Recovery图1Air Cooled Water Chiller with Heat Recovery图2

Air Cooled Water Chiller with Heat Recovery

$0.00
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Air Cooled Water Chiller with Heat Recovery Condition: New Certification: ISO, CE, CCC Noise Level: Low Compressor Number: 1 Selected Voltage: 380V/50HZ Unit Structure: Integral Cooling Method: Air-cooled Type: Air-Cooled Usage: Heating/Cooling + Hot Water Trademark: Tili Transport Package: Standard Exporting Package Origin: Guangdong Province HS Code: 8418619000 Product Description 1)Saving energy:COPup to 8.322)Operating range: -10 to 48 degree3) Noise level low to 54dB(A)4) Smart control based on module combination5) High efficiency H.E.6) Air Cooled absorption chiller with Heat Recoveryi) Installation:ii) Inner system:Model No.EKAC230BRSREKAC460BRSREKAC690BRSREKAC920BRSREKAC1150BRSREKAC1380BRSRAir conditioning modeNominal cooling capacitykw65.5131196.5262327.5393Nominal heating capacitykw69138207276345414Nominal cooling input powerkw19.438.858.277.697116.4Nominal heating input powerkw19.238.557.776.996.2115.4Water flow rate for nominal cooling capacitym3/h11.322.533.845.156.367.6Water flow rate for nominal heating capacitym3/h11.923.735.647.559.371.2Hot water modeNominal water supply capacitykw16.332.74965.481.798Nominal heating capacitykw76152228304380456Total power of nominal heating capacitykw18.436.755.173.591.8110.2Cooling + heat recovery modeNominal cooling capacitykw59.7119.4179.1238.8298.5358.2Nominal heat recovery capacitykw76152228304380456Nominal input powerkw16.332.648.965.281.597.8Nominal water supply capacity at heat recovery sidem3/h16.332.648.965.281.597.8Nominal water flow atevaporator sidem3/h10.320.530.841.151.361.6Power supplyv/ph/hz380/3/50Flow controlElectronic expansion valveRefrigerantR22Heat exchanger typeAir conditioning sidem³/hbraze-welded panel-type heat exchangerhot water sidem³/hHigh-efficiency bucket heat exchangerCompressorQtySet24681012FanQtySet24681012WaterresistanceAir conditioning sidekPa454545454545hot water sidekPa757575757575Minimumdiameter forwater pipesAir conditioning sideinch≥2≥3≥3≥4≥4≥5hot water sideinch≥2≥3≥4≥4≥5≥5DimensionsL×Hmm2012×1840Widthmm88021253370461558607105Power cable specificationSection area of live linemm²≥10≥35≥70≥95≥120≥150Qty.of live lines3Section area of null linemm²≥4Qty.of live lines1Section area of grounding linemm²≥10≥16≥35≥50≥60≥75Qty.of grounding lines1Net weightkg60012001800240030003600Operation weightkg62012401860248031003720Note:1. Air conditioning mode: Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172 m3/(h@kW); outdoor ambient temperature35°C. Test conditions for nominal heating capacity: outlet water temperature: 45°C; water flow: 0.172 m3/(h@kW); temperature of outdoor dry/wet bulb: 7°C/6°C.2. Cooling + Heat recovery mode Test conditions for nominal cooling capacity: Hot water side: temperature of outlet water 45°C, water flow 0.215 m3/(h@kW); Airconditioning side: temperature of outlet water 7°C, water flow 0.172 m3/(h@kW);3. Hot water mode: Test conditions for nominal water flow: Ambient temp: 20/15°C; outlet water temp: 45°C; water flow of cooling + heat recovery mode.4. Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.5. Water resistance at the hot water side includes water pressure drop of the unit and does not include the pressure drop at the Y-shaped filter and othercomponents.6. Pipes outside the unit need to be customized and installed on site. The diameter of the pipes must meet design requirements. TILI does not provide the pipes.7. Full heat recovery units and other units can be combined to form partial heat recovery modular system. Full heat recovery units can also be combined to form atotal heat recovery system. Modular units can be formed using the 1~16 basic modules. The above table lists the parameters for common module combinations.8. For on-site electric wiring, see the name plate or installation menu of the unit.
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product