1/5
Advanced Anesthesia System for Operation Room for Adult  Pediatric and Infant图1Advanced Anesthesia System for Operation Room for Adult  Pediatric and Infant图2

Advanced Anesthesia System for Operation Room for Adult Pediatric and Infant

$2.00 / Piece
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: Advanced Anesthesia System for Operation Room for Adult, Pediatric and Infant Model NO.: M-HA9600 Group: Children and Adult Certification: CE, ISO13485 Type: Anesthesia Machine Classification: Physiological Functions of Diagnosis and Monitoring Equipment Display: Digital Screen Ventilation Mode: Ippv, Sippv, Manual, Stby Gas Source O2: 0.45MPa +- 0.05MPa Gas Source N2o: 0.45MPa +- 0.05MPa Power Source: AC:100V-240V 50/60Hz Vaporizer Station: 2 Flowmeters: 4-Tube Flowmeters Back up Power Supply: Not Less Than 8hours Yoke System: Optional Patient Monitor: Optional Tital Volume: 10-1500ml Vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane Trademark: Medbes Transport Package: Wooden Specification: 1m3, 110kgs Origin: China HS Code: 9018907010 Product Description M-HA9500 Anesthesia MachineDisplay:Digital screenVentilation Mode:IPPV,SIPPV,MANUAL,STBYGasSource:O2: 0.45Mpa±0.05MpaN2O: 0.45Mpa±0.05MpaPower Source:AC:100V-240V 50/60HzSpecification:ModelM-HA9500DisplayDigital screenVentilation ModeIPPV,SIPPV,MANUAL,STBYGasSourceO2: 0.45Mpa±0.05MpaN2O: 0.45Mpa±0.05MpaPower SourceAC:100V-240V 50/60HzFeatures*Classic electropneumatic ventilator,widely apply for adults and children;*High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%;*Sophisticated monitoring of anesthesia respiratory parameters and alarm functions;*Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense;*Advanced gas-electric isolation system eliminates the oxygen enrichment;*With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours.*Modular design reduces potential leaks, misconnections and detachments of tube;*Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit;*Large- capacity CO2absorption system;*AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff.Precise Control*The minimum tidal volume can be low to 10ml;*Adopt international top control valves, sensor components;*Sophisticated information control system.Anesthetic Evaporator*Two Vaporizer station ;*Temperature compensation function,;*Flow compensation function ;*Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow.Breathing Circuit*Modular design, original anti-water technology;*Large-capacity CO2 absorption tank (1.6L) ;*Easy to take part .Alarm Function*Tidal volume limit alarm, minute ventilation volume limit alarm;*Gas shortage alarm, battery shortage alarm;*Power failure alarm; *Continuous airway high pressure alarm.M-HA9600 Anesthesia MachineSpecification:ModelM-HA9600Ddiplay5.6"LCD ScreenVentilation ModeIPPV,SIPPV,MANUAL,STBY,SIGH,SPONTGasSourceO2: 0.45Mpa±0.05MpaN2O: 0.45Mpa±0.05MpaPower SourceAC:100V-240V 50/60HzFeatures*Classic electropneumatic ventilator,widely apply for adults and children;*High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%;*Sophisticated monitoring of anesthesia respiratory parameters and alarm functions;*Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense;*Advanced gas-electric isolation system eliminates the oxygen enrichment;*With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours.*Modular design reduces potential leaks, misconnections and detachments of tube;*Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit;*Large- capacity CO2absorption system;*AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff.Precise Control*The minimum tidal volume can be low to 10ml;*Adopt international top control valves, sensor components;*Sophisticated information control system.Anesthetic Evaporator*Two Vaporizer station ;*Temperature compensation function,;*Flow compensation function ;*Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow.Breathing Circuit*Modular design, original anti-water technology;*Large-capacity CO2absorption tank (1.6L) ;*Easy to take part .Alarm Function*Tidal volume limit alarm, minute ventilation volume limit alarm;*Gas shortage alarm, battery shortage alarm;*Power failure alarm; *Continuous airway high pressure alarm;*Oxygen limit alarm.M-HA9800 Anesthesia MachineSpecification:ModelM-HA9800Ddiplay10.4"LCD bulid-in screenVentilation ModeIPPV,SIPPV,PCV,PEEP,MANUAL,STBY,SIGHGasSourceO2: 0.45Mpa±0.05MpaAir:0.45Mpa±0.05MpaN2O: 0.45Mpa±0.05MpaPower SourceAC:100V-240V 50/60HzFeatures*Classic electropneumatic ventilator,widely apply for adults and children;*High-precision four-tube flowmeters; nitrous oxide-oxygen anesthesia to ensure that the oxygen concentration is not less than 25%;*Sophisticated monitoring of anesthesia respiratory parameters and alarm functions;*Humanized interface, clearly shows the working state of the anesthesia machine, with a more comfortable operation feeling and visual sense;*Advanced gas-electric isolation system eliminates the oxygen enrichment;*With standard large-capacity maintenance-free battery, the machine can work continuously for not less than 8 hours.*Modular design reduces potential leaks, misconnections and detachments of tube;*Classic rising bellows can monitor the patient's breathing and detect leakproofness of circuit;*Large- capacity CO2absorption system;*AGSS (optional) can effectively control pollution of anesthetic waste gas, clean surgical room, care for health of medical staff.Precise Control*The minimum tidal volume can be low to 10ml;*Adopt international top control valves, sensor components;*Sophisticated information control system.Anesthetic Evaporator*Two Vaporizer station ;*Temperature compensation function,;*Flow compensation function ;*Pressure compensation function; *Precise concentration output ensures safe operation of low flow and micro flow.Breathing Circuit*Modular design, original anti-water technology;*Large-capacity CO2absorption tank (1.6L) ;*Easy to take part .Alarm Function*Tidal volume limit alarm, minute ventilation volume limit alarm;*Gas shortage alarm, battery shortage alarm;*Power failure alarm; *Continuous airway high pressure alarm;*Oxygenlimit alarm.Others:
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product