1/5
AC Hysteresisgraph Steel Magnetic Testing Machine图1AC Hysteresisgraph Steel Magnetic Testing Machine图2

AC Hysteresisgraph Steel Magnetic Testing Machine

$0.00
FOB Price:
Negotiable | Get Latest Price
Order Quantity:
1 Set / Sets
Supply Ability:
1000 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
5 days
Hot in store
Product Details
Product Name: AC Hysteresisgraph Steel Magnetic Testing Machine Model NO.: 201SA Oil Cylinder Position: Under Power Source: AC220V Weight: 100-500Kg Control: Computer Control Display: Digital Loading Method: Static Load Load Way: Electronic Load Accuracy Grade: 0.5 Maxcapacity: <1000KN Type: Universal Testing Machine Mass Scope of Workpiece: <900kg Max Diameter of Workpiece: <500mm Trademark: LJ Transport Package: Wooden Carton Origin: China HS Code: 850300 Product Description 201SA Hysteresisgraph is fully automatic, computer controlled equipment to measure on basic magnetization curve and magnetic hysteresis loop at a dynamic state for soft magnetic material at frequency of 20Hz to 500 kHz, automatic measurement of magnetic hysteresis loop of the soft magnetic materials such as silicon steel, precision alloy, non-crystal and ferrite, accurate measurement on the dynamic magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, loss iron Pc, remanence Br and coercivity Hc.The controlling of computer and A/D sampling replace the traditional analog bridge, frequency meter, ammeter, voltage meter, power meter, the whole testing process is automatic completed.Applied StandardsGB/T 3658-2008 Methods of AC magnetic properties of magnetically soft materialsGB/T 19346-2003 Methods of AC magnetic properties of amorphous and nanocrystalline soft magnetic alloysSJ 20966-2006 Measuring methods for soft ferrite materialsIEC 60404-6 Methods of AC magnetic properties of magnetically soft materialsMeasured ParametersAmplitude permeability(µa)Loss angle (δ)Total loss ratio (Ps)Remanence (Br)Coercivity (Hc)B(H) hysteresis loopB(H) hysteresis loop clusterB(H) magnetization curveµa(H) permeability curvePs(B) loss curveCalculate μ′, μ″, μL, μR, Q and Ai under certain conditionsMain Features1.Testing samples: soft magnetic ferrite, permalloy, amorphous ,nanocrystalline and iron powder core.2.Test sample shapes: ring, E and U shapes.3.Test samples with closed magnetic circuit can be directly winded and measured on samples. Magnetizing coil (N1) and measuring coil (N2) form a no-load transformer.4.Non-inductive resistance connected on magnetizing coil loop to determine magnetizing current and magnetic field intensity through the measurement of pressure drop on non inductive resistance, magnetic field peak value can be locked through digital feedback, magnetic field lock precision 0.5%.5.Magnetic induction obtained through digital integration of coil measuring voltage, magnetic induction peak value locked through digital feedback, magnetic induction lock precision 0.5%.6.Power source and sampling amplifier integrated into a casing with simple interface: one RS232 interface connected to the computer, two way voltage alarm connected to high speed A/D card. 7.Measuring dynamic hysteresis loop through volammetry and digital integration can accurately measure dynamic magnetic characteristic parameters such as μa, δ, Pc, Br and Hc, and calculate μ, μ, μL, μR, Q and AL, etc.8.Automatic and continuous measurement up to 255 testing points, the testing time of every testing point is about 12 seconds, fixed-frequency or fixed Bm optional in multipoint test.9.Powerful function of the software, the technical request to the testing staff is very low.Software Functions1. Operate under Windows7, complied to Windows software restricts, easy to operate.2. Lock Bm (magnetic induction) and lock Hm (magnetic field) can be selected, fit for various measurement requirements.3. Automatic control, intelligent judgment, without user intervention all through the progress.4. Sampling waveform and instrument status under real-time monitoring, and can be stopped at any time.5. The effective sectional area and length of magnetic path of samples can be calculated according to the overall dimension of samples.6. System adopts database format, can directly print or output test result to Excel form.7. Various file management functions: data saving and deleting, remove all the data etc. 8. Data files contain complete sampled data, sample parameters, instrument parameters and testing schemes, adopt text format, can be conveniently typed into other software.9. Display I(t), U(t) and B(t) sampling waveform and B(H) hysteresis loop, and coordinate message at every data point on the curve10. Multipoint cluster, can display B(H) magnetic hysteresis loop cluster, B(H) magnetization curve, μa(H) permeability curve and Ps(B) loss curve, and it can display coordinate message at every data point on the curve.11. B(H) magnetization curve and Ps(B) damage curve measured under different conditions can be combined on one drawing for comparative analysis.12. Set up upper and lower limits according to μa, Ps, Bm, Br, Hc and Hm, etc. Qualify test result and determine through the color of data table.13. Print preview function, can conveniently regulate the size and edge distance of test report.14. Test report can be directly printed, or generate JPG image file. JPG image file can be sent directly through E-mail, or saved into disk.15. Test reports contain complete curve diagrams, test results, test conditions and sample parameters. Both Chinese and English format can be adopted to facilitate adding user mark and enterprise name.16. Optional multiple unit systems satisfies the application habits of different users.Technical Parameters1. According to National Standard GB/T 3658-2008, under the frequency of 20Hz~20kHz, technical data of measuring of permalloy ring sample are as follows:ParametersPs(%)μa(%)δ(%)Bm(%)Hm(%)Uncertainty(k=2)33-11Repeatability± 1.5± 1.5± 1.5± 0.5± 0.5Remarks1. Samples should be thin ring, OD/ND<1.4.2. Measure by lock Bm and Bm=100mT~200mT; demagnetizing before testing and frequency of demagnetizing should be less than or equal to test frequency.3. Uncertainty is "-", means there is no requirement in the National Standard.2. According to National Standard GB/T 19346-2003, under the frequency of 20kHz~100kHz, technical data of measuring of amorphous ring sample are as follows:ParametersPs(%)Ss(%)μa(%)δ(%)Bm(%)Hm(%)Uncertainty(k=2)553-12Repeatability± 3± 2.5±2±2± 0.5±1Remarks1. Samples should be thin ring, OD/ND<1.5.2. Measure by lock Bm and Bm=100mT~200mT; demagnetizing before testing and frequency of demagnetizing should be less than or equal to test frequency.3. Uncertainty is "-", means there is no requirement in the National Standard.3. According to Military Standard SJ 20966-2006, under the frequency of 20kHz~100kHz, technical data of measuring of ferrite ring sample are as follows:ParametersPs(%)μa(%)δ(%)Bm(%)Br(%)Hc(%)Uncertainty(k=2)53-1--Repeatability± 3± 2± 2± 0.5±1±1Remarks1. Samples should be thin ring, OD/ND≈1.67.2. Measure by lock Bm and Bm=100mT~200mT; demagnetizing before testing and frequency of demagnetizing should be less than or equal to test frequency.3. Uncertainty is "-", means there is no requirement in the National Standard.Hardware ParametersTechnical Data201SA /200K201SA /500K201SA /K50201SA K100Max. Output Power300 VA sine wave(below 100kHz)200 VA sine wave(below 300kHz)500VA sine wave1000 VA sinewave(5kHz~40kHz)650VA sinewave(40kHz~100kHz)Frequency Range20Hz ~ 200 kHz1kHz ~500kHz1kHz ~200kHz5 kHz ~ 100 kHzFrequency Fineness< 0.1%×Current ValueFrequency Error< 0.05%Output Voltage0~ 50V(Peak Value)0~ 50V(Peak Value)0 ~ 50V~ 100V~150V~300V0 ~ 50V~ 100V~150V~300VVoltage FinenessProgram Control 1 mV, panel < 10 mVProgram Control 1 mV, panel < 10 mVProgram Control 1 mV, panel < 0.1%xcurrent rangeProgram Control 1 mV, panel < 0.1%xcurrent rangeVoltage Distortion FactorSuperior to 1%Superior to 0.5%Voltage StabilitySuperior to 0.1%Sampling Current0~15A0~10A6.33mA~20A6.33mA~20ASampling Voltage0~50V0~50V(peak value)1V~316VMeasurement materialssoft magnetic ferrite, permalloy, amorphous and nanocrystallineSample shapetoroid, E and U shapesSample sizeNo physical limitation, size affects the max H field,Test Time12sOperating temperature range23±5ºCA/D cardPC5012 A/D CardPC6684 A/D CardConfigurationSerial No.Product NameModelQua.UnitRemarks1Hysteresisgraph201SA1set2Data Acquisition CardPC6684 or PC5012(Insert in computer)1pieceInstall in computer3Measurement SoftwareSMTest (Install in computer)1set4ComputerAdvantech IPC1setWith 18.5 inch monitor5PrinterHP1108 laser printer1setBlank laser printer6Standard SpecimenRing1piece7Cabinet1setCAUTION:As the products of our company are in constant updates, the change of products without pre-notice.
Contact with Supplier

Inquiry title*

main content*

company

Name*

Telephone*

Email*

QQ

Ali Wangwang

30 inquiries available today
At present, times have been inquired
You can also inquire times
Recommend product